The Nice HighLoad-Control is a compact flush-mounted module for switching a single electrical load of up to 16 A (3680 W at 230 V). The module is powered by 230 V AC, 50 Hz and is designed for resistive loads, such as electric underfloor heating, electric radiators and electric water heaters. It can be operated via the Z-Wave network or a connected momentary or toggle switch.
In addition to switching devices, the HighLoad-Control offers two thermostat modes. With an external NTC temperature sensor, the module can control heating based on the measured temperature. Temperature control via the Z-Wave controller is also possible, with the NTC sensor acting as an additional temperature input, for example to monitor the floor temperature. This allows you to use the same module for switching electrical devices and controlling electric heating.
The HighLoad-Control is equipped with a Z-Wave 800 chip and measures the active power and energy consumption of the connected device. The module also supports mains voltage measurement.
Features
- Power supply 230 V AC / 50 Hz; switches a single resistive load of up to 16 A / 3680 W
- Three operating modes: switch, thermostat with NTC sensor and thermostat with temperature control via the Z-Wave controller
- Suitable for applications including electric underfloor heating, electric radiators and electric water heaters
- Measures active power (W), energy consumption (kWh) and mains voltage (V)
- Z-Wave 800 with support for S2 security and repeater functionality
- Works with momentary and toggle switches
- Configurable auto-off timer in switch mode
- Built-in protection against overcurrent and internal overheating
- Compact design measuring 45 × 36 × 23 mm; flush box at least 60 mm deep
- A live and neutral wire are required for installation
Please note: The thermostat functions require an external NTC temperature sensor; it is not included. The NTC input is connected to mains voltage; treat the sensor and its wiring as live conductors. Temperature control via the controller also requires inclusion in a Z-Wave network. Mains voltage reporting is disabled by default and can be enabled in the settings.
| Actors: | Switch |
|---|---|
| Communicatie & Protocol: | Z-Wave |
| IP value: | IP20 |
| In accordance with guidelines: | 2011/65/EU 2015/863 2014/53/EU |
| Installation method: | Flush mount |
| Maximum load capacity: | 16A |
| Operating humidity: | 0-95% relative humidity without condensation |
| Operating temperature: | 0-35 °C |
| Outputs: | 1 |
| Power source: | 230V AC 50Hz |
| Protocol: | Z-Wave (800 series chip) |
| Supported load types: | Resistive |
| Transmit power: | +6 dBm |
| Wireless frequency: | 868.4 or 869.8 MHz EU |